banner_elec_15
Guide to New Extensions
Application Form
Distribution Wires Tariff
Energy Requirements
Terms and Conditions
Forms and Publications
New Page 1
Ready for Launch – A Yukon Waterway Legend

Offer to purchase Manning REA assets

ATCO Electric Participation in AESO Open Houses

 

ATCO Electric is responsible to install and own the appropriate metering and the associated meter costs will be included as part of the proposal for electric service.

The Customer Metering and Service Manual below provides direction and guidance for customers, consultants, and electrical contractors either requiring or installing an electrical service that will be energized by ATCO Electric. This manual provides specifications for metering configurations for most services under 5,000 Volts. Special arrangements can be made for installing service connections not specified in this manual, with approval prior to installation.

Customer Metering and Service Manual (1106 KB)

Acrobat and the Acrobat logo are trademarks of Adobe Systems Incorporated.

Selecting a Meter

The meter selection table provides a listing of meters approved by Measurement Canada and ATCO Electric for use on industrial and oilfield projects. The table also includes a list of specific output information available from the meters. Selection of a meter for a project can be made by contacting your ATCO Electric account representative.

Manufacturer

Model

Type

Units Of Measure
Display [Mass Memory]

Options

Schlumberger

Sentinel

Interval

kW.h, w.d, va.d [+/- w.h, +/- VAR.h]

Built-in analog modem for external analog cellular telephone, built-in RS232 board for external digital cellular telephone, external pulse outputs for customer equipment, master/slave capability.

Schlumberger

Vectron

Cumulative

kW.h, w.d, va.d

 Built-in TWACS AMR

Schlumberger

K2S

Cumulative

kW.h

 

Schlumberger Centron Cumulative kW.h  Built-in TWACS AMR

General Electric

I-70S

Cumulative

kW.h

 Built-in TWACS AMR

General Electric

KV2

Interval

kW.h, w.d, va.d [+/- W.h, +/- VAR.h, V²h, A²h]

Built-in analog modem for external analog cellular telephone, built-in RS232 board for external digital cellular phone, external pulse outputs for customer equipment, master/slave capability.

General Electric

VIM

Cumulative

kW.h, w.d, va.d

Built-in RS232 board for external TWACS AMR.

Transdata

Mark V

Interval

kW.h, w.d, va.d [+/- W.h, +/- VAR.h]

Built-in digital cellular telephone.  Optional 8 channel Mass Memory Board.  Optional SCADA Port.

Elster

D5S

Cumulative

kW.h

 Built-in TWACS AMR